Equipment fault guides
Plain answers to the fault codes and alerts we see most often on solar systems, with what our own monitoring and service records show.
ABB
- ABB/FIMER inverter E031 Error Read V: what it means and what to do
ABB/FIMER error E031 shows as "Error Read V" with the Alarm LED. The manual calls it "Output relay damaged": the inverter measured too great a voltage difference between the input and output of its grid-connection relay. FIMER classifies it as an error inside the inverter that cannot be checked externally, and if it persists after the inverter is switched off and back on, the remedy is to contact FIMER customer assistance.
- ABB/FIMER inverter E050 arc fault: what it means and what to do
ABB/FIMER error E050 shows as "AFDD Activated" or "Arc Fault" with the GFI LED. It means the inverter's arc fault protection has detected a possible arc on the DC (solar panel) side and has disconnected from the grid. Because an arc can come from damaged wiring or connectors, have a technician inspect the system before it is reset.
- ABB/FIMER inverter Missing Grid: what it means and what to do
"Missing Grid" on an ABB/FIMER inverter means the inverter is not detecting any voltage on its AC (grid) side, so it cannot connect and produce power. It often follows warning W003 "Grid Fail", which FIMER uses when the grid voltage is absent or unstable. During a power outage this is expected; if your home has power and the message stays, a technician needs to check the AC supply to the inverter.
- ABB/FIMER inverter Riso Low (E025): what it means and what to do
"Riso Low" on an ABB/FIMER inverter means that before connecting to the grid, the inverter measured the insulation resistance of the solar array to ground and found it below 1 megohm, so it does not connect. FIMER logs this as error E025, although that number is not shown on the display. Common causes include damaged panels, moisture in junction boxes, and poor connections, and the check has to be made by a technician.
Enphase
- Enphase 'AC Frequency Out of Range' (ACFOOR): what it means
"AC Frequency Out Of Range", abbreviated ACFOOR by Enphase, means your microinverters measured the utility grid frequency outside the range they accept and paused production. Enphase describes these events as usually brief and caused on the utility side, and it is not an emergency. Note the time in the app, check whether production returns after a short pause, and make sure the solar breakers are on, switching one on once only if it is off. Do not open any equipment; if it keeps coming back, ask your utility about grid problems in your area and contact a professional.
- Enphase 'AC Voltage Out of Range' (ACVOOR): causes and fixes
"AC Voltage Out Of Range", abbreviated ACVOOR by Enphase, means your microinverters measured the utility voltage outside the range they accept and paused production. Enphase notes utility voltage varies and the condition often corrects itself, so it is not an emergency. Note the time in the app, check whether production returns, and make sure the solar breakers are on, switching one on once only if it is off. Do not open any equipment; if it keeps coming back, ask your utility about the voltage at your home and contact a professional, because wiring, breaker or utility-transformer problems are possible causes.
- Enphase 'DC Voltage Too Low': what it means and what to do
Enphase says this event is usually normal in low light, at dawn and dusk. The microinverter is reporting that the voltage coming from its panel is too low. If it does not clear in full daylight, the panels may be heavily shaded or covered in snow. It is not urgent. Check from the ground for snow or shade, and call a professional if it keeps happening in full daylight.
- Enphase 'Device failed to report': what it means and what to do
A device on your Enphase system, normally a microinverter, did not report to the gateway. Enphase microinverters talk to the gateway over the building's power lines, so low light, an outage or electrical interference can interrupt it. It is not urgent. First wait for good daylight and see whether the device reports again in the Enphase App.
- Enphase 'Device produced no power': what it means and what to do
One or more of your devices, normally microinverters under the panels, has not produced power. It can be harmless, such as low light, snow, or a utility outage, or it can point to a communication problem or a faulty microinverter. It is not an emergency, but check it soon. Look at the app and the gateway lights, and call for service if it continues.
- Enphase 'Device Produced No Power': why and what to do
"Device produced no power" means at least one Enphase microinverter reported no energy for the period. Causes range from night, snow or a tripped breaker to a grid problem, a communication fault or a failed microinverter. In the Enphase App this escalates to a Low Solar Production error when more than one microinverter has produced nothing for five days. Check the time and look at the panels from the ground, read the gateway's Power Production light from outside (red means at least one microinverter is not producing), and confirm the solar breaker is on, switching it on once only and leaving it off if it trips again. Never open panels, microinverters or enclosures, and call for service if production stays at zero in good daylight.
- Enphase 'Gateway Not Reporting' Error: how to get it back online
In the Enphase App this shows as a "Gateway Not Reporting" error: your IQ Gateway (or older Envoy) has lost its internet connection, so the Enphase cloud is not receiving data. It usually points to a router, Wi-Fi or power problem rather than panels that stopped working. Check your internet, then read the gateway's network light from outside: solid green is connected, flashing green is trying, amber or red means local network only, and off means no network. Restart your router, make sure the gateway's breaker is on (switching it on once only), and do not open the gateway or any enclosure; call a professional if it stays offline after one restart.
- Enphase 'Low Solar Production' Error: causes and what to do
"Low Solar Production" is the Enphase App error, shown as Production Issue to installers, raised when your system makes less energy than expected. Clouds or snow can trigger it while the system is working normally, and so can dirt, shade, a tripped breaker or a fault in one or more microinverters. Check the weather, look at the panels from the ground, and compare panels in the app's Array view; if a solar breaker has tripped, reset it once and watch for 24 hours. Do not climb onto the roof or clean the panels yourself, and ask for a diagnosis if the same panels keep underperforming on clear days.
- Enphase Battery Below Reserve Alert: what it means and what to do
Enphase sends a Battery Charge alert when your IQ Battery drains below the reserve level you set, or below a 10 percent warning threshold. It describes the battery level, not a fault. During an outage, if the charge reaches the shutdown level at night, backup pauses until solar is available: systems with IQ8 microinverters resume with sunlight, while older systems check for sun at 9:30 a.m. Turn off large appliances, wait for sun or grid power, check the Enphase App, and review your reserve setting. If you ever see swelling, heat, smell or smoke from the battery, keep away from it, switch it off only if you can do so safely as described in your manual, and call a professional.
- Enphase gateway: not reporting — what it means and what to do
The Enphase cloud has stopped receiving data from your IQ Gateway. That usually points to a connection or power problem at the gateway rather than panels that have stopped working. It is not urgent, but it is worth fixing so monitoring and alerts work. Start by checking that other devices in your home are online, then look at the gateway's network light.
Fronius
- Fronius state 107 no AC grid detected: what it means and what to do
Fronius state 107 "No AC grid detected" means the inverter is not producing because it cannot detect a stable AC grid. Fronius notes that 107 also shows if the grid was only temporarily absent, for example during a power failure or shutdown. Grid codes like this clear by themselves once the grid is back within limits; if 107 stays on while your home has power, Fronius advises contacting your installer.
- Fronius state 240/241 arc detection: what it means and what to do
Fronius state codes 240 to 243 mean the inverter's integrated arc detection has triggered. Fronius explains that the inverter detects and extinguishes serial arcs by switching off the power, and that the state code must be reset manually before it feeds power again. Fronius's advice to owners is to contact your installer to check the system, and that reset should come after the inspection, not before.
- Fronius state 307 or 306 PV voltage low: what it means and what to do
Fronius state 306 "PV POWER LOW" and 307 "PV VOLTAGE LOW" mean the panels are not supplying enough power or voltage for the inverter to feed the grid, so it pauses and returns to its startup phase. Fronius states that both codes appear naturally every morning and evening because of low sunlight and are not the result of a fault. They only need attention if they persist in good sunlight.
- Fronius state 475 insulation error: what it means and what to do
Fronius state 475 means the inverter's automatic insulation measurement found too low a resistance between the solar array and ground, so it stops feeding power to the grid. Code 502 is the warning version of the same problem, shown while the inverter keeps running. Fronius says there may be a problem with the panels or their cabling and that it often happens only in certain conditions such as rain; its advice is to contact your installer.
- Fronius state 509 no power fed in: what it means and what to do
Fronius state 509 means the inverter has fed no energy into the grid in the last 24 hours. Fronius explains that this happens when not enough power is available from the panels, for example when they are covered with snow, dirt or leaves. It is a warning that stays on the display until acknowledged, and Fronius advises watching for any other state codes, which usually point to the real cause.
Generac
- Generac PV Link Low Sun status: what it means and what to do
"Low Sun" on a Generac PV Link means the PV Link is not getting enough voltage from the solar panels to run. Generac says every PV Link shows Low Sun at night, after sunset, or when panels are covered. Low Sun while the sun is shining points to a problem with the solar input to that PV Link, not with the REbus wiring.
- Generac PV Link Offline: what it means and what to do
A PV Link that shows "Offline" on its PWRcell inverter device page has talked to the inverter before but has lost that connection. Generac lists the causes as the PV Link DC disconnect being opened, the PV Link's communication channel (PLM channel) no longer matching the inverter, or damage to the REbus wiring. While offline, that PV Link's solar panels do not deliver power.
- Generac PWRcell battery blinking red: what it means and what to do
On a Generac PWRcell battery, a red status light blinking rapidly (every half second) means the battery is in an Error state. A slow red strobe about every 8 seconds means Sleeping, which is normal after the battery runs down during an outage.
- Generac PWRcell Battery Not Ready: what it means and what to do
"Battery Not Ready", or a battery that stays in the Waiting state (orange light strobing every 2 seconds), means the PWRcell battery cannot start up and join the system. Generac lists causes such as the battery disconnect switch being off, an incomplete connection between battery modules, battery communication cables out of order, or blown battery fuses.
- Generac PWRcell inverter not connected to internet: what to do
When the Internet light on the Generac PWRcell inverter control panel is off, the inverter is not connected to Generac's server, so remote monitoring cannot see live data. A slowly strobing blue Internet light is different: it means a firmware update is in progress. Generac's troubleshooting step is to make sure the inverter is connected to the internet through your router.
- Generac PWRcell Island Overload: what it means and what to do
"Island Overload" on the Generac PWRcell inverter screen means that during a grid outage your home tried to draw more power than the PWRcell system can supply. The inverter protects itself by shutting off power and retrying at increasing intervals, so backup power cycles on and off. Generac says the inverter light alternates between blinking green and solid red.
LG
- LG RESU 10H battery recall: what it means and what to do
LG Energy Solution Michigan recalled LG Chem RESU 10H home batteries in December 2020, August 2021 and October 2022 because they can overheat and pose a risk of fire and harmful smoke. The 2020 and 2021 recalls cover batteries whose serial number begins with R15563P3 and offer a free replacement. The 2022 recall uses a remote software update that monitors the cells and shuts the battery down if a fire risk is detected.
- LG RESU battery FAULT light on: what it means and what to do
When the FAULT light on the front of an LG Chem RESU battery is on, the battery is in a warning state because a condition such as voltage or temperature is outside its design limits. LG says the inverter stops operating when a warning is reported, and the warning clears on its own if the battery returns to normal. If it does not clear, the battery needs a qualified technician.
- LG RESU battery not charging: what it means and what to do
If your LG Chem RESU battery's ON light is lit but it never shows Charging or Discharging, LG's manual points first to the inverter: firmware versions and the inverter's battery settings. On SolarEdge systems, a battery state of energy below 10% that keeps falling while solar is producing is a related symptom. SolarEdge's first step for that is a battery self-test, which your installer runs.
- LG RESU with SolarEdge Error 3x6B: what it means and what to do
On a SolarEdge inverter, "Error 3x6B" means Battery communication error: the inverter has lost communication with the battery, such as an LG Chem RESU, which LG lists as compatible with SolarEdge inverters. SolarEdge's fix is to make sure the RS485 and Enable (En) wires between battery and inverter are connected correctly and that the battery is set up correctly in the inverter.
SMA
- SMA event 1302 waiting for grid voltage: what it means and what to do
SMA event 1302 appears with the messages "Waiting for grid voltage", "Grid connection installation failure" and "Check grid and fuses". SMA explains that either a line or the neutral conductor is not connected, or the utility grid has failed. If the power is out in your area, the inverter waits for feed-in conditions to be met and starts feeding in again once they are; if your home has power and 1302 stays on, a technician needs to check the AC side.
- SMA event 3501 insulation failure: what it means and what to do
SMA event 3501 means the inverter has detected a ground fault in the solar array. Sunny Boy TL-US models show "Insulation resist." with "Check generator"; newer -US models show "Insulation failure" with "Check generator". SMA explains that the electrical insulation between the PV system and ground is defective or insufficient, and its corrective step, checking the system for ground faults, is for a qualified person. Do not touch the panels or racking, and book a technician.
- SMA event 4301 electric arc detected: what it means and what to do
SMA event 4301 means the inverter's arc-fault circuit interrupter (AFCI) has detected an electric arc in the solar (DC) wiring and has stopped feeding power. Older Sunny Boy TL-US models show "Electr. arc detected" with "Check generator"; newer -US models show "Serial el.arc in String ... detected by AFCI mod.", often naming the affected string. SMA treats the fix as work for a qualified person: the system is shut down and the panels, cables and connections are checked for damage. Leave the system as it is and book a technician.
- SMA event 7702 Interference device: what it means and what to do
On SMA Sunny Boy TL-US inverters, event 7702, like the whole range 7701 to 7712, appears as "Self diagnosis" with "Interference device". SMA's manual says the cause must be determined by the SMA Service Line, and its only corrective measure is to contact SMA. There is nothing for an owner to reset, so note the code and book a technician who can work through the case with SMA.
- SMA event 8206 electric arc detected: what it means and what to do
SMA event 8206 "Electr. arc detected" means the inverter has detected an electric arc and will not feed power until someone confirms that any damage has been repaired. On Sunny Boy TL-US models the display adds "Please confirm by tapping"; on newer -US models SMA calls this state operation inhibition. Confirming is meant to come after a qualified person has inspected the panels, DC wiring and connectors, so do not tap the inverter or reset it yourself.
SolarEdge
- SolarEdge 'Inverter Production Issue Detected': what it means
"Inverter - Production issue detected" is a general SolarEdge monitoring alert that the inverter is not producing as expected. SolarEdge's own guidance is to rule out weather first and then read the inverter's error log, because the specific cause shows there as an error code such as a grid voltage, isolation or arc fault. From the ground, check for snow, shade or debris on the panels, note whether the inverter shows a red light, and confirm the solar breaker is on. Do not climb on the roof or open the inverter, and contact a professional if the alert persists in full sun so they can pull the error log.
- SolarEdge 'No Communication With Power Optimizer': what to do
"No communication with Power Optimizer" is the SolarEdge alert raised when a power optimizer, the small box under a panel, has sent no data for 24 hours. Shade or snow, a loose connection, a failed optimizer or a lost pairing can cause it, and the rest of the system usually keeps producing. Open the Layout view in the monitoring app to see which panel is dark, check from the ground for snow, leaves or new shade, and recheck in full sun. Do not climb on the roof or touch panels, optimizers or wiring, and contact a professional if the same optimizer stays silent in full sun.
- SolarEdge 'No Communication With the Inverter': what to do
"No communication with the Inverter" is the SolarEdge monitoring alert raised when one inverter has not reached SolarEdge's servers for at least 3 hours. The cause is often your home network, but it can also mean the inverter is off, for example after a tripped breaker. Check your router and internet, look from a safe distance for the inverter's steady blue light, and make sure the solar breaker is on; if it is off, switch it on once only and do not keep resetting it if it trips again. Contact a professional if the inverter shows a red light or the alert does not clear.
- SolarEdge 'No Communication With the Site' Alert: what to do
This alert, which SolarEdge names "No communication with the site", means none of the inverters or devices at your home are reaching SolarEdge's servers. Usually the internet connection or Wi-Fi has dropped, not the panels, and the inverter can keep producing while it is offline. Check that your router is on and other devices are online, look from a safe distance for the inverter's blue light (steady blue means it is communicating), and restart your router once. Do not open the inverter or change its settings, and contact a professional if it has not come back within a day.
- SolarEdge "Battery - circuit breaker tripped" alert: what to do
This alert means the battery's circuit breaker tripped. SolarEdge warns that if the problem is not fixed the battery self-discharges and can drain to an unrecoverable state within several days, so act soon. SolarEdge's restart sequence involves the inverter, battery and disconnect switches and is for qualified installers. Note the alert details and call a professional.
- SolarEdge "Battery connection error" alert: what it means
SolarEdge's alert list shows "Battery connection error" with the single instruction to contact SolarEdge support. It does not list homeowner steps. Note the alert and time in the SolarEdge app or portal, do not open the battery or touch its wiring, and contact a professional or SolarEdge support.
- SolarEdge "Inverter not producing - Energy Limit mode" alert: what it means
SolarEdge lists this alert as a production issue: the inverter is not producing. Its documented checks concern power optimizers that stopped communicating and re-pairing the inverter, which are installer tasks. Note the alert and time in the SolarEdge app or portal, then contact a professional or SolarEdge support. Do not open the inverter.
- SolarEdge Error 18x37 / 18x38 (Grid Voltage): causes and fixes
This alert means the inverter measured grid voltage outside its allowed range and stopped producing to protect itself and the grid. On current SolarEdge inverters it shows as error 18x37 (V-Line Max, voltage too high) or 18x38 (V-Line Min, voltage too low); older screen models show AC Voltage Too High or Too Low. The inverter reconnects by itself once voltage is back in range, so wait, recheck the app, and note the time of day it happens. Make sure the solar breaker is on, switching it on once only if it is off, and contact a professional if it keeps coming back.
- SolarEdge Error 18x86 (Isolation Fault): causes and what to do
SolarEdge error 18x86, shown as 2x19 or Error 25 on older screen models, is an isolation fault: the inverter found the solar array is not properly isolated from ground, which can mean a ground fault in the DC wiring. Treat it as urgent. Switch the system off with the inverter ON/OFF switch, do not restart it repeatedly, and do not touch the panels, wiring, racking, optimizers or the inverter case. Call a professional; SolarEdge states only a certified PV installer should fix the faulty string.
- SolarEdge Error 18xC (Arc Fault Detected): what to do now
SolarEdge error 18xC, Arc Fault Detected (also shown as 18xD or 3x11 on some models), means the inverter detected a possible electrical arc in the solar DC circuit and stopped producing. Treat this as urgent. Switch the system off with the inverter ON/OFF switch, do not restart it repeatedly, and do not open the inverter or any box or touch any wiring. Call a professional to inspect before the system is turned back on, and call 911 if you see smoke or fire or smell burning.
- SolarEdge Error 3x6E (No Communication With the Meter): fix
"No communication with the Meter" is the SolarEdge alert raised when the energy meter has not reported for at least a full day; on the inverter the same fault shows as error 3x6E, Meter Comm. Error. It is not a safety warning and production usually continues, but consumption and export data in the app will be missing or wrong. Check the app for gaps and note any error shown on the inverter, but do not open the inverter or touch meter cables. A technician needs to check the meter wiring and the connection to the inverter.
- SolarEdge External Fan Fault (Fan Failure Warning): what to do
"External fan fault" is the SolarEdge monitoring alert for one of the inverter's external cooling fans not working; older screen models show it as a Fan Failure warning (Warning 1 to 4, 6 or 7). SolarEdge's steps are to check the fan cable, clean the fan, replace it, and open a support case if that does not help. All of that means working on the equipment, so a technician should handle it. From outside, make sure nothing is blocking the area around the inverter, do not open it or touch the fan, and schedule service soon.
- SolarEdge Grid Frequency Error (18x40, 18x43, 2x22, 2x23): fixes
This alert means the inverter detected the grid's AC frequency outside its allowed range and paused production. On current SolarEdge inverters it appears as an error from 18x40 to 18x5D (for example 18x40, frequency too high, or 18x43, too low); older screen models show AC Freq Too High (2x22) or AC Freq Too Low (2x23). It is usually a grid event and clears on its own, so wait and recheck the app. Make sure the solar breaker is on, switching it on once only if it is off, and contact a professional if it repeats, since country settings and AC checks are technician work.
SunPower
- SunPower Internet Communication Down: what it means and what to do
"Internet Communication Down" (ICD) means your SunPower monitoring device, the PV Supervisor (PVS5 or PVS6), is not reaching the internet over your home Wi-Fi, ethernet or cellular backup. The app (mySunPower, now SunStrong Connect) stops updating. SunStrong notes the panels may still be producing; only the monitoring data is missing.
- SunPower panel orange or red in app: what it means and what to do
In the panel view of the mySunPower (SunStrong Connect) app, an orange panel has stopped communicating with the PVS monitoring device, and a red panel has stopped producing power. Grey means a temporary loss of production or communication and is normal. SunPower's guidance is to allow 48 hours for grey panels and to contact your installer for orange or red ones.
- SunPower SunVault manual reset required: what it means and what to do
If your SunVault battery stops powering your home during an outage, the mySunPower app may show a popup saying a manual reset is required. SunPower says this usually happens when home loads exceed SunVault's maximum power level while it is running in backup. The reset needs large appliances turned off first and the system connected to the internet.
Tesla
- Tesla Powerwall Breaker Open alert: what it means and what to do
A "Breaker Open" alert in the Tesla app means the AC breaker that connects your Powerwall to your home electrical system is off, so Powerwall is disconnected and cannot store or supply energy. Tesla says another sign is that the LED light on the right side of the Powerwall does not turn on. The breaker needs to be switched back on, but only if there are no signs of heat damage.
- Tesla Powerwall Device Offline: what it means and what to do
"Device Offline" in the Tesla app means your Powerwall system has lost its internet connection, so the app cannot show recent power flow or energy data. Tesla's troubleshooting page also calls this Gateway Offline: the power flow screen is grayed out or blank, or the Gateway beeps. Powerwall keeps running in its last mode and still backs up your home during an outage; you only lose remote monitoring and software updates.
- Tesla Powerwall Disabled alert: what it means and what to do
"Powerwall Disabled" with the banner "Service Required - Fault Detected" means one or more Powerwall functions have been switched off because of an internal fault that requires replacement. Tesla's instruction is to turn off the Powerwall enable switch and contact your installer to schedule a replacement.
- Tesla Powerwall Meter Offline: what it means and what to do
"Meter Offline" means one of the energy meters in your Tesla system has stopped reporting, so the Tesla app cannot show some or all of your power flows. Tesla lists the signs as part of the power flow data missing, the battery level stuck at 0% for several days, or the battery below 10% and not charging. Tesla lists a battery stuck at a low charge as one of the signs.
- Tesla Powerwall Waiting for Solar: what it means and what to do
"Waiting for Solar" means Powerwall ran too low on energy during a grid outage and stopped powering your home. Tesla says it will check for solar every hour in daylight and resume once there is enough sun to power the home and charge. If those retries fail you may see "Waiting for User Input" and then "Waiting for Grid". A related alert, "Powerwall Overloaded", means your home asked for more power than Powerwall can supply.
- Tesla Solar Production Limited alert: what it means and what to do
"Solar Production Limited" with the banner "Service Required - Fault Detected" means one of your inverters may not be producing solar because a fault was detected in your solar system. Tesla's instruction is to contact your installer to schedule a site visit.
Tigo
- Tigo CCA status light red or yellow: what it means and what to do
The light on a Tigo Cloud Connect Advanced (CCA) shows the status of your monitoring and rapid shutdown system. Steady green means everything is working. Solid red means the CCA cannot reach your network or Tigo's servers, often because of a changed Wi-Fi password, a firewall or weak signal. Solid yellow means a warning, such as data not uploading or fewer optimizers found than expected. A dark light can mean the system is in rapid shutdown or the CCA has no power.
- Tigo EI app gray panel (no data): what it means and what to do
A gray panel in the Tigo Energy Intelligence (EI) app or portal means Tigo is not receiving monitoring data for that module. Tigo lists common causes as a communication issue, radio interference, a module that has not been discovered yet, or a recently replaced Tigo device that has not been updated in the portal. A gray panel shows missing data, not necessarily missing power: Tigo optimizers let the rest of the string keep producing even if one unit fails.
- Tigo EI error 203 PV Isolation Low: what it means and what to do
Tigo EI inverter error code 203 "PV Isolation Low" means the inverter has detected a low resistance to ground, pointing to an issue with the DC wiring or a panel. It is often called an isolation resistance or R-Iso error. Tigo states that troubleshooting must only be done by qualified personnel, so keep clear of the system and book a technician.
- Tigo EI inverter error 200 AFCI fault: what it means and what to do
Tigo EI inverter error code 200 "AFCI Fault" means the inverter has detected an arc fault in the solar (PV) wiring. Tigo says the inverter shows a continuous red fault light with a loud buzzer, and it will not reconnect to the grid until it is reset. The electrical code requires that reset to be done manually on site, so book a technician to find the cause before anyone resets it.