Enphase 'AC Frequency Out of Range' (ACFOOR): what it means
"AC Frequency Out Of Range", abbreviated ACFOOR by Enphase, means your microinverters measured the utility grid frequency outside the range they accept and paused production. Enphase describes these events as usually brief and caused on the utility side, and it is not an emergency. Note the time in the app, check whether production returns after a short pause, and make sure the solar breakers are on, switching one on once only if it is off. Do not open any equipment; if it keeps coming back, ask your utility about grid problems in your area and contact a professional.
Can wait
What causes this fault?
- The utility grid frequency was briefly outside the allowed range.
- A utility outage or switching event in your area.
- A wiring or AC problem on the property, which only an installer can test.
What can I safely try myself?
- Note the alert Open the Enphase App and write down the alert text and the time it appeared.
- Check whether it is a one-off Look at your production graph. If production returns after a short pause, the grid has settled.
- Check the solar breaker Make sure the solar breakers are on. If one is off, switch it on once only. Do not open any panel cover.
- Check with the utility Enphase says to verify with your utility that the line voltage and frequency are in range. Ask whether there are outages or grid work in your area.
- Watch for a repeat If the alert returns, record the dates and times to give to your installer or service provider.
When should I call a professional?
Call a professional if the alert repeats on several days or production stays at zero after the grid is stable. Otovo services these systems and can diagnose this fault. Do not open any equipment or touch wiring.
Frequently asked questions
- Is this a fault in my solar system?
- Often not. A flashing red status light on a microinverter means the AC grid is absent or not within specification, which can come from the utility side.
- Who can I ask about the grid?
- Your electric utility. Enphase advises checking with the utility that the line voltage and frequency are in range.
- Can I change the limits myself?
- No. Only a qualified installer working with Enphase should review grid settings.
- Do I need to restart anything?
- No. Check the breaker once and wait. Do not repeatedly switch equipment on and off.
- What does ACFOOR mean on Enphase?
- ACFOOR is Enphase's short name for AC Frequency Out Of Range: a microinverter reported that the utility frequency was too low or too high for its grid limits and stopped exporting until it returned to normal.
- Will an Enphase AC Frequency Out of Range error fix itself?
- Usually. Enphase describes frequency events as typically transient and self-correcting by the utility. If it persists or affects many days, a technician should check with the utility and review the grid profile.
Other Enphase faults
- Enphase 'DC Voltage Too Low': what it means and what to do
- Enphase 'Device failed to report': what it means and what to do
- Enphase gateway: not reporting — what it means and what to do
- Enphase 'Device produced no power': what it means and what to do
- Enphase 'Low Solar Production' Error: causes and what to do
- Enphase 'Gateway Not Reporting' Error: how to get it back online
- Enphase 'Device Produced No Power': why and what to do
- Enphase 'AC Voltage Out of Range' (ACVOOR): causes and fixes
- Enphase Battery Below Reserve Alert: what it means and what to do