SolarEdge Error 18x37 / 18x38 (Grid Voltage): causes and fixes

This alert means the inverter measured grid voltage outside its allowed range and stopped producing to protect itself and the grid. On current SolarEdge inverters it shows as error 18x37 (V-Line Max, voltage too high) or 18x38 (V-Line Min, voltage too low); older screen models show AC Voltage Too High or Too Low. The inverter reconnects by itself once voltage is back in range, so wait, recheck the app, and note the time of day it happens. Make sure the solar breaker is on, switching it on once only if it is off, and contact a professional if it keeps coming back.

Can wait

What causes this fault?

  • Utility voltage is temporarily too high or too low.
  • Voltage is high at your home because of local grid conditions or the length of the AC wiring.
  • The inverter's country or grid setting is wrong.
  • The AC connection to the inverter has a problem.

What can I safely try myself?

  1. Note the alert Record the alert, the time, and whether it says voltage too high or too low.
  2. Wait for the grid to settle Give the inverter some time to restart on its own and recheck the app.
  3. Check the breaker Make sure the solar breaker in your panel is on. If it is off, switch it on once only.
  4. Look for a pattern If the error recurs at the same time each day, tell the technician. That helps them decide whether to involve the utility.

When should I call a professional?

Otovo services these systems and can diagnose this fault for you. Call if the error keeps returning. Settings, wiring, and conversations with the grid operator about protection values should be handled by a qualified technician.

Frequently asked questions

Can I fix this myself?
Usually it is a matter of waiting. Do not change inverter settings or open the inverter.
Is it a safety issue?
The inverter stops on its own when voltage is out of range, which is designed behavior.
Do I need to call the utility?
If it keeps happening, a technician can check and consult the grid operator if needed.
What does SolarEdge error 18x37 mean?
18x37 is V-Line Max: AC grid voltage at the inverter is above the limit for its country setting. SolarEdge lists a wrong country setting, high utility voltage, or voltage rise on an undersized AC wire run as causes.
What does SolarEdge error 18x38 mean?
18x38 is V-Line Min: grid voltage is below the allowed limit. SolarEdge's remedies are checking the country setting and consulting the grid operator, both jobs for a technician or the utility.
Is 18x37 high voltage or low voltage?
High. SolarEdge's own documents list 18x37 as voltage too high (legacy error 55) and 18x38 as too low (legacy error 56). Some third-party pages have these reversed.

Plain text version