SolarEdge fault guides

Plain answers to the fault codes and alerts we see most often on solar systems, with what our own monitoring and service records show.

  • SolarEdge 'Inverter Production Issue Detected': what it means

    "Inverter - Production issue detected" is a general SolarEdge monitoring alert that the inverter is not producing as expected. SolarEdge's own guidance is to rule out weather first and then read the inverter's error log, because the specific cause shows there as an error code such as a grid voltage, isolation or arc fault. From the ground, check for snow, shade or debris on the panels, note whether the inverter shows a red light, and confirm the solar breaker is on. Do not climb on the roof or open the inverter, and contact a professional if the alert persists in full sun so they can pull the error log.

  • SolarEdge 'No Communication With Power Optimizer': what to do

    "No communication with Power Optimizer" is the SolarEdge alert raised when a power optimizer, the small box under a panel, has sent no data for 24 hours. Shade or snow, a loose connection, a failed optimizer or a lost pairing can cause it, and the rest of the system usually keeps producing. Open the Layout view in the monitoring app to see which panel is dark, check from the ground for snow, leaves or new shade, and recheck in full sun. Do not climb on the roof or touch panels, optimizers or wiring, and contact a professional if the same optimizer stays silent in full sun.

  • SolarEdge 'No Communication With the Inverter': what to do

    "No communication with the Inverter" is the SolarEdge monitoring alert raised when one inverter has not reached SolarEdge's servers for at least 3 hours. The cause is often your home network, but it can also mean the inverter is off, for example after a tripped breaker. Check your router and internet, look from a safe distance for the inverter's steady blue light, and make sure the solar breaker is on; if it is off, switch it on once only and do not keep resetting it if it trips again. Contact a professional if the inverter shows a red light or the alert does not clear.

  • SolarEdge 'No Communication With the Site' Alert: what to do

    This alert, which SolarEdge names "No communication with the site", means none of the inverters or devices at your home are reaching SolarEdge's servers. Usually the internet connection or Wi-Fi has dropped, not the panels, and the inverter can keep producing while it is offline. Check that your router is on and other devices are online, look from a safe distance for the inverter's blue light (steady blue means it is communicating), and restart your router once. Do not open the inverter or change its settings, and contact a professional if it has not come back within a day.

  • SolarEdge "Battery - circuit breaker tripped" alert: what to do

    This alert means the battery's circuit breaker tripped. SolarEdge warns that if the problem is not fixed the battery self-discharges and can drain to an unrecoverable state within several days, so act soon. SolarEdge's restart sequence involves the inverter, battery and disconnect switches and is for qualified installers. Note the alert details and call a professional.

  • SolarEdge "Battery connection error" alert: what it means

    SolarEdge's alert list shows "Battery connection error" with the single instruction to contact SolarEdge support. It does not list homeowner steps. Note the alert and time in the SolarEdge app or portal, do not open the battery or touch its wiring, and contact a professional or SolarEdge support.

  • SolarEdge "Inverter not producing - Energy Limit mode" alert: what it means

    SolarEdge lists this alert as a production issue: the inverter is not producing. Its documented checks concern power optimizers that stopped communicating and re-pairing the inverter, which are installer tasks. Note the alert and time in the SolarEdge app or portal, then contact a professional or SolarEdge support. Do not open the inverter.

  • SolarEdge Error 18x37 / 18x38 (Grid Voltage): causes and fixes

    This alert means the inverter measured grid voltage outside its allowed range and stopped producing to protect itself and the grid. On current SolarEdge inverters it shows as error 18x37 (V-Line Max, voltage too high) or 18x38 (V-Line Min, voltage too low); older screen models show AC Voltage Too High or Too Low. The inverter reconnects by itself once voltage is back in range, so wait, recheck the app, and note the time of day it happens. Make sure the solar breaker is on, switching it on once only if it is off, and contact a professional if it keeps coming back.

  • SolarEdge Error 18x86 (Isolation Fault): causes and what to do

    SolarEdge error 18x86, shown as 2x19 or Error 25 on older screen models, is an isolation fault: the inverter found the solar array is not properly isolated from ground, which can mean a ground fault in the DC wiring. Treat it as urgent. Switch the system off with the inverter ON/OFF switch, do not restart it repeatedly, and do not touch the panels, wiring, racking, optimizers or the inverter case. Call a professional; SolarEdge states only a certified PV installer should fix the faulty string.

  • SolarEdge Error 18xC (Arc Fault Detected): what to do now

    SolarEdge error 18xC, Arc Fault Detected (also shown as 18xD or 3x11 on some models), means the inverter detected a possible electrical arc in the solar DC circuit and stopped producing. Treat this as urgent. Switch the system off with the inverter ON/OFF switch, do not restart it repeatedly, and do not open the inverter or any box or touch any wiring. Call a professional to inspect before the system is turned back on, and call 911 if you see smoke or fire or smell burning.

  • SolarEdge Error 3x6E (No Communication With the Meter): fix

    "No communication with the Meter" is the SolarEdge alert raised when the energy meter has not reported for at least a full day; on the inverter the same fault shows as error 3x6E, Meter Comm. Error. It is not a safety warning and production usually continues, but consumption and export data in the app will be missing or wrong. Check the app for gaps and note any error shown on the inverter, but do not open the inverter or touch meter cables. A technician needs to check the meter wiring and the connection to the inverter.

  • SolarEdge External Fan Fault (Fan Failure Warning): what to do

    "External fan fault" is the SolarEdge monitoring alert for one of the inverter's external cooling fans not working; older screen models show it as a Fan Failure warning (Warning 1 to 4, 6 or 7). SolarEdge's steps are to check the fan cable, clean the fan, replace it, and open a support case if that does not help. All of that means working on the equipment, so a technician should handle it. From outside, make sure nothing is blocking the area around the inverter, do not open it or touch the fan, and schedule service soon.

  • SolarEdge Grid Frequency Error (18x40, 18x43, 2x22, 2x23): fixes

    This alert means the inverter detected the grid's AC frequency outside its allowed range and paused production. On current SolarEdge inverters it appears as an error from 18x40 to 18x5D (for example 18x40, frequency too high, or 18x43, too low); older screen models show AC Freq Too High (2x22) or AC Freq Too Low (2x23). It is usually a grid event and clears on its own, so wait and recheck the app. Make sure the solar breaker is on, switching it on once only if it is off, and contact a professional if it repeats, since country settings and AC checks are technician work.