SolarEdge Error 3x6E (No Communication With the Meter): fix
"No communication with the Meter" is the SolarEdge alert raised when the energy meter has not reported for at least a full day; on the inverter the same fault shows as error 3x6E, Meter Comm. Error. It is not a safety warning and production usually continues, but consumption and export data in the app will be missing or wrong. Check the app for gaps and note any error shown on the inverter, but do not open the inverter or touch meter cables. A technician needs to check the meter wiring and the connection to the inverter.
Can wait
How common is this fault?
- We have seen this fault on 340 SolarEdge systems, 3.8% of the 8,936 SolarEdge systems we monitor (last 12 months, as of October 2026).
- Once it appears, the system usually clears it in about 503.8 hours (median), and 0% clear within 24 hours.
- Source: Otovo fleet monitoring and service records, data as of October 2026.
What causes this fault?
- A loose connection on the meter or the inverter communication board.
- A damaged or disconnected communication cable between the meter and the inverter.
- A meter that has lost power or failed.
What can I safely try myself?
- Note the alert Record the alert text and when it began in the SolarEdge app.
- Check the inverter display or lights Look at the inverter from outside. If it shows a meter communication error, write it down.
- Check your data Look in the app for gaps in consumption or export data.
- Do not open anything Do not open the inverter or touch meter cables. Schedule a technician.
When should I call a professional?
Otovo services these systems and can diagnose this fault for you. Call a technician to check the wiring and the meter connection to the inverter, which requires opening equipment.
Frequently asked questions
- Is my solar still producing?
- Check production in the app. The alert is about meter data, and consumption or export data may be incomplete.
- Why does the alert wait a day?
- SolarEdge raises it only if there was no communication for a full day.
- Is it urgent?
- It is not a safety warning, but it should be fixed so your monitoring data is accurate.
- What is SolarEdge error 3x6E?
- 3x6E is SolarEdge's Meter Communication Error: the inverter cannot communicate with the energy meter it is configured to use. Older firmware shows the same fault as error 185.
- Does SolarEdge error 3x6E stop my solar from producing?
- Usually not. It is a metering and data fault. Production can continue, but the app's consumption and import or export figures will be incomplete until the meter link is repaired.
Other SolarEdge faults
- SolarEdge "Inverter not producing - Energy Limit mode" alert: what it means
- SolarEdge "Battery connection error" alert: what it means
- SolarEdge "Battery - circuit breaker tripped" alert: what to do
- SolarEdge Grid Frequency Error (18x40, 18x43, 2x22, 2x23): fixes
- SolarEdge Error 18x86 (Isolation Fault): causes and what to do
- SolarEdge 'No Communication With Power Optimizer': what to do
- SolarEdge 'Inverter Production Issue Detected': what it means
- SolarEdge 'No Communication With the Site' Alert: what to do
- SolarEdge 'No Communication With the Inverter': what to do
- SolarEdge Error 18x37 / 18x38 (Grid Voltage): causes and fixes
- SolarEdge External Fan Fault (Fan Failure Warning): what to do
- SolarEdge Error 18xC (Arc Fault Detected): what to do now