Between November 2025 and November 2026, the most common alert in Otovo's US monitored fleet was a lost connection, not a broken part. The figures below are the same public, aggregated fault statistics that our equipment fault guides publish, as of November 9, 2026. They contain no customer or site detail.
What are the most common solar system faults in 2026?
- As of November 9, 2026, the most common alert in Otovo's US monitored fleet was SolarEdge's "No site communication": 2,988 of the 8,928 SolarEdge systems we monitor (33.5%) showed it at least once in the previous 12 months.
- As of November 9, 2026, the most common Enphase alert was "Enphase system alert: Your system stopped communicating", on 890 of the 4,991 Enphase systems we monitor (17.8%) over the previous 12 months, followed by "Device failed to report" on 713 systems (14.3%).
- As of November 9, 2026, seven of the ten most common alerts in the US fleet report a lost connection to monitoring or to a device (site, inverter, gateway, optimizer or meter), not a failed component.
- As of November 9, 2026, SolarEdge's isolation fault ("DC Isolation - Sensitive") showed on 161 monitored systems (1.8%) and its arc fault on 85 (1.0%) in the previous 12 months; only 7.0% of isolation alerts older than 24 hours had cleared within 24 hours.
- As of November 9, 2026, Enphase's gateway-offline alert had a median time to clear of 309.1 hours (about 13 days) and 0.0% cleared within 24 hours, against 71.6 hours (about 3 days) and 3.0% for SolarEdge's site-offline alert.
Which faults are most common, by brand?
Each row counts the monitored systems that raised the alert at least once in the previous 12 months, as of November 9, 2026. Where a row links, the link opens our guide for that fault, with the safe steps and when to call a professional. "Cleared" means the monitoring vendor stopped reporting the condition, not that anyone repaired it.
SolarEdge alerts (8,928 monitored SolarEdge systems)
| Alert, in the vendor's words | Systems with at least one alert | Share of this brand's monitored systems | Median hours to clear | Cleared within 24 hours | Latest alert in the data |
|---|---|---|---|---|---|
| No site communication | 2,988 | 33.5% | 71.6 | 3.0% | October 2026 |
| No communication with the Inverter | 1,161 | 13.0% | 47.7 | 5.0% | October 2026 |
| Inverter production issue detected | 1,156 | 12.9% | 29.8 | 3.0% | October 2026 |
| No communication with Power Optimizer | 661 | 7.4% | 167.5 | 1.0% | October 2026 |
| No communication with the Meter | 340 | 3.8% | 503.8 | 0.0% | October 2026 |
| Grid voltage | 279 | 3.1% | 30.0 | 4.1% | October 2026 |
| Inverter not producing - Energy Limit mode | 277 | 3.1% | 42.0 | 1.3% | October 2026 |
| No string communication | 204 | 2.3% | 167.4 | 1.8% | October 2026 |
| INVERTER_BELOW_THRESHOLD_LOW_VOLTAGE_CANDIDATE | 178 | 2.0% | 40.8 | 0.5% | October 2026 |
| DC Isolation - Sensitive | 161 | 1.8% | 29.6 | 7.0% | October 2026 |
| Inverter has detected an arc fault | 85 | 1.0% | 81.8 | 0.0% | October 2026 |
| Battery not charging | 76 | 0.9% | 117.8 | 0.0% | October 2026 |
| Battery connection error | 62 | 0.7% | 41.1 | 0.7% | October 2026 |
| Grid frequency | 55 | 0.6% | 34.0 | 2.5% | October 2026 |
| External fan fault | 30 | 0.3% | not published | 0.0% | October 2026 |
| Battery - circuit breaker tripped | 28 | 0.3% | not published | 4.5% | October 2026 |
Enphase alerts (4,991 monitored Enphase systems)
| Alert, in the vendor's words | Systems with at least one alert | Share of this brand's monitored systems | Median hours to clear | Cleared within 24 hours | Latest alert in the data |
|---|---|---|---|---|---|
| Enphase system alert: Your system stopped communicating | 890 | 17.8% | 309.1 | 0.0% | November 2026 |
| Device failed to report | 713 | 14.3% | 312.8 | 0.0% | November 2026 |
| Gateway not reporting | 529 | 10.6% | not published | 0.0% | November 2026 |
| Device produced no power | 503 | 10.1% | 173.8 | 0.0% | November 2026 |
| AC Frequency Out Of Range | 371 | 7.4% | 425.3 | 0.0% | August 2026 |
| AC Voltage Out Of Range | 276 | 5.5% | 752.4 | 0.0% | June 2026 |
| Device produced no power | 267 | 5.3% | 497.7 | 0.0% | August 2026 |
| Enphase system alert: Low Solar Production | 176 | 3.5% | not published | 0.0% | November 2026 |
| DC Voltage Too Low | 113 | 2.3% | not published | 0.0% | August 2026 |
| Enphase system alert: Battery charge level is below 50% | 26 | 0.5% | not published | 0.0% | November 2026 |
Source: Otovo fleet monitoring records, public equipment-fault statistics for the United States (/api/v1/public/equipment-faults), retrieved November 9, 2026. "Not published" means the fault had fewer than 20 measurable alerts, so the figure is withheld rather than estimated.
How long do these faults take to clear?
The median is the middle time from an alert opening to the vendor clearing it. For SolarEdge's site offline alert it is 71.6 hours, for inverter communication it is 47.7 hours and for inverter production issues it is 29.8 hours. For Enphase's gateway offline alert it is 309.1 hours. A short median does not make a fault harmless: a system that stops reporting is also a system you cannot see.
How was this measured, and what are the limits?
- Monitored fleet. The systems that Otovo monitors in the United States through the manufacturer's own monitoring platform, counted per brand as live monitoring connections. It is our customers' systems, not a random sample of solar systems in the country, and the brand mix reflects who we serve.
- Period. Alerts first seen in the 12 months before the data date. The data date is November 9, 2026; the last column of each table shows the month of the latest alert behind each fault.
- What is counted. Systems with at least one alert of that kind, not the number of alerts, and not the number of repairs. Storm alerts, utility grid events and monitoring-portal configuration alerts are not equipment faults and are left out.
- Publication threshold. A fault is listed only when it appeared on at least 20 distinct monitored systems. A timing figure needs at least 20 measurable alerts.
- Timing. Dismissed alerts, alerts closed at the instant they opened, and alerts that closed through the vendor's automatic expiry at about 90 days are left out of the timing figures, so very long-running alerts are under-represented. The 24-hour share is taken over alerts older than 24 hours.
- Brands. Only SolarEdge and Enphase appear for the US, because only they have faults at 20 or more monitored systems on the public list.
Does this show which brand is most reliable?
No. Do not use these figures to rank brands. The monitored fleet is not a fair sample: it reflects the systems Otovo services, the age and size of each brand's systems in it, and how each vendor's monitoring decides to raise and word an alert. A higher share for one brand can mean its platform raises more alerts, not that its equipment fails more.
What should I do if my system shows one of these alerts?
Start with the guide for your brand and alert on our repair guides: each gives the safe steps and says when to stop and call a professional. Treat isolation and arc faults as urgent and keep clear of the panels, wiring and inverter. If you want a technician to look at your system, see solar repair.